Stainless steel process piping in a production plant
The core heating element

Tubular Heaters

A resistance coil centered in a metal sheath and insulated with compacted magnesium oxide; formable to many shapes.

Tubular heating element and its cross-section Terminal pins Heated length Cold end Metal sheath MgO insulation Resistance coil

Schematic illustration drawn for ECC, not to scale.

01Product description

The tubular element is the building block of most immersion, circulation and air heaters. A resistance wire coil is centered inside a metal tube and electrically insulated by magnesium oxide (MgO) powder, which is compacted to improve heat transfer. The element can be bent into hairpins, coils and custom shapes.

02Operating principle

Current through the resistance coil generates heat. Compacted MgO conducts that heat to the sheath while keeping the coil electrically insulated. Terminal pins at the cold ends connect to the supply; the cold sections do not generate heat.

03Industrial applications

  • Liquid immersion (as single elements or in assemblies)
  • Air and gas heating, bare or with fins
  • Surface heating when clamped or cast into metal
  • Ovens, dryers and process equipment

04Technical characteristics

  • Several standard diameters
  • Sheath materials: copper, steel, stainless steel, INCOLOY® and others
  • Heated length and cold ends specified to the application
  • Formable into custom shapes
  • Terminations suited to moisture or temperature

05Advantages

  • Robust and versatile
  • Wide range of powers, voltages and shapes
  • Electrically insulated, metal-sheathed construction

06Selection variables

  • Medium being heated, its chemistry and its viscosity across the temperature range
  • Required power (kW) for heat-up and for holding temperature, including heat losses
  • Operating temperature and maximum allowable sheath temperature
  • Allowable watt density for the medium and flow condition
  • Sheath material compatible with the medium and the temperature
  • Supply voltage, number of phases and circuit arrangement
  • Terminal enclosure rating for the installation area (general purpose, moisture-resistant or hazardous location)
  • Temperature control and over-temperature protection
  • Element diameter, heated length and cold-end length
  • Bend geometry and mounting

07Installation considerations

  • Keep the heated length fully in the medium or the designed heating zone; cold ends belong in the fitting or wall.
  • Respect the minimum bend radius specified by the manufacturer.
  • Protect terminals from moisture and contamination.

08Technical information

The surface area of a tubular element per inch of heated length depends only on its diameter.

Area per inch (in²/in) = π × d
A (in²) = π × d × Lh
Element diameterArea per inch of heated length (π × d)
1/4 in (0.250)0.785 in²
5/16 in (0.3125)0.982 in²
3/8 in (0.375)1.178 in²
7/16 in (0.4375)1.374 in²
0.475 in1.492 in²
1/2 in (0.500)1.571 in²

Worked example

A straight 2.5 kW element of 0.475 in diameter with 50 in of heated length:

A = π × 0.475 × 50 = 74.6 in²
WD = 2,500 W ÷ 74.6 in² = 33.5 W/in²

Recommended maximum operating temperatures by sheath material (UL 1030): copper 350 °F, steel and iron 750 °F, MONEL® 900 °F, 300-series stainless steel 1200 °F, INCOLOY® 1600 °F, INCONEL® 1700 °F.

Request information on tubular heaters

Share your application data; we will reply with the next steps and a quotation where possible.

Related technologies